:: Network Communications Options for Yaskawa A1000 600V Drive ::
NuCo Drives, L.L.C.1724 Tomich Court
Crest Hill, IL 60403
Toll Free (866) 639-3933
Fax: (815) 725-9393
E-mail: info@nucodrives.com
A1000 600V AC Drive
A1000 600V AC Drive
Specifications and Features for A1000 600V Drive
Models & Ratings for A1000 600V Drive
Network Communications Options for A1000 600V Drive
Input, Output, and Keypad Options for A1000 600V Drive
1-30 Horsepower
The Drive for the Future . . . Today
Network Communications Options for A1000 600V Drive
These communication cards provide the interface between industrial networks and Yaskawa AC drives. These options may be factory installed or field installed.
Compare this drive's Network Communications Options to other Yaskawa AC drives.
| Network Communications Option | Option Card # & Mounting Location |
Installation Manual | Technical Manual & Latest Support File |
| DeviceNet™ With ADR - Each DeviceNet network
supports up to 63 drives. Controllers are available from many PLC and/or
PC suppliers.
The DeviceNet network communications option board is designed to comply
with all pertinent aspects of the ODVA (Open DeviceNet Vendor Association)
specification and AC drive profile. All parameters, diagnostics, and
operational commands are accessible via DeviceNet. Automatic Device Replacement
(ADR) is supported in this DeviceNet option, including the functions
of Auto Baud Rate sensing and Faulted Node Recovery (using Group 4 messaging).
The DeviceNet satellite board mounts integrally in the drive and provides
a DeviceNet standard open tap connector. Electronic Data Sheets (EDS)
may be downloaded to assist with network configuration and drive setup. |
SI-N3 CN5-A |
TOBPC73060043 | SIEPC73060043 EDS File |
| EtherNet/IP - This option complies with the EtherNet/IP
protocol specification. This allows for communication over 10/100 Mbps
Ethernet networks. This
option has the ability to configure the IP Address from a user specified
IP address, from a DHCP host, or from a BootP host. All parameters, diagnostics
and operational commands are accessible via EtherNet/IP. Auto-tuning
the motor is also possible through this option using the DriveWizard
PC program. |
SI-EN3 CN5-A |
TOEPYEACOM04 | SIEPYEACOM04 EDS File |
| MECHATROLINK-II - This option is designed for connecting a drive to a field network using the MECHATROLINK protocol. The MECHATROLINK-II option allows the user to operate the drive, monitor the status, and change parameters from a MECHATROLINK master device at a communication speed up to 10Mbps. | SI-T3 CN5-A |
TOBPC73060050 | SIEPC73060050 |
| Modbus TCP/IP - This option complies with the Modbus TCP/IP protocol specification. This allows for Modbus communication over 10/100 Mbps Ethernet networks. This option has the ability to configure the IP Address from a user specified IP address, from a DHCP host, or from a BootP host. All parameters, diagnostics and operational commands are accessible via Modbus TCP/IP. Auto-tuning the motor is also possible through this option using the DriveWizard PC program. This option supports up to 10 simultaneous PLC/PC connections. | SI-EM3 CN5-A |
TOEPYEACOM05 | SIEPYEACOM05 |
| Modbus RTU RS-232 - Complies with a subset of Modicon's Modbus RTU specification, referred to as Memobus by Yaskawa. All parameters, diagnostics and operational commands are accessible. The RS-232 Modbus RTU network allows for one drive to be accessed by the controller. | Embedded CN2-2 |
N/A | SIEPC71061631 |
| Modbus RTU RS-485 - Complies with a subset of Modicon's Modbus RTU specification, referred to as Memobus by Yaskawa. All parameters, diagnostics and operational commands are accessible. Each RS-485 Modbus RTU network supports up to 32 drives. | Embedded Terminal Strip |
N/A | SIEPC71061631 |
| PROFIBUS-DP - This option complies with the Profibus- DP protocol specification. All parameters, diagnostics and operational commands are accessible via Profibus. The option board provides a 9-pin (F) type D-Sub connector for easily connecting to a standard Profibus style, shielded twisted-pair cable. Each Profibus network supports up to 99 drives. This option supports all of the Profibus data rates from 9.6 Kbps to 12 Mbps. Up to 32 bytes of input data and 32 bytes of output data are provided per message transaction. Sync and Freeze modes are supported for groups. Profibus DP-V1 support (cyclic and acyclic data exchange). Configurable PPO read and write parameters. The option is configured using parameters within the drive, which allows for easy configuration eliminating the use of hardware switches. Status LEDs are viewable through the front cover, and a monitor has been added to allow for improved diagnostics. | SI-P3 CN5-A |
TOBPC73060042 | SIEPC73060042 GSD File |
Download communications software files from this website through the Downloads section/Network Support Files.
NuCo Drives is happy to Quote any projects, simply e-mail us at info@nucodrives.com and attach your specifications.
We'll send you a detailed quote as soon as possible.
Copyright @ 2010 Yaskawa Electric America, Inc. All Rights Reserved.
:|: Home :|: Products :|: Services :|: About
Us :|: Contact Us :|:
Privacy Policy :|: Copyright
Notice :|: Site Map :|: